skip to footer block
TOS Elk Products Alarm Output Director; Separates single output to 2 ELK 941 P2303122TOS-ELK-941 https://cdnimages.opentip.com/full/TOS/TOS-ELK-941.jpg Elk Products Alarm Output Director; Separates single output to 2 ELK 941 Manufacturer part number: ELK-941The ELK-941 separates the steady or pulsing voltage from a single alarm output and directs this into two (2) different relay outputs. This is ideal for activating a two channel long-range radio or cellular transmitter, a two channel siren, strobe light, or bell from the single alarm outputs found in most alarm control panels. A steady voltage input activates Relay 1 (typical for burglary) while a pulsing voltage input activates Relay 2 (typical for fire). A 3 to 4 second verification delay time occurs before the relays activate. Either relay can be set to ignore the delay time and provide an immediate output for installations requiring a siren or bell test. A separate output is available for triggering a low current sounder or LED during the delay time. An optional jumper configures Relay 2 to pulse in a temporal coded bell pattern which meets ANSI Standard S3.41 for fire signaling. The input trigger can be either positive or negative (pull to ground).FeaturesSeparates Steady and Pulsing Voltage and directs it into Two (2) Different Relay OutputsPositive or Negative Low Current TriggerTwo (2) SPDT Relay OutputsIdeal For Two (2) Channel Long Range Radio or Cellular TransmittersOption For Temporal Pulse On Relay 2Low Current Output During Delay TimeLED Indication of Relay StatusSurface Mount ABS Enclosure with Snap-On CoverMeets ANSI S3.41 Audible Emergency Evacuation Signals 3-Pulse PatternLifetime Limited Warranty Specifications:Operating Voltage: 12 Volts DCCurrent Draw: 96mA (both relays on)Pulsing Input: .1 - 4sec. (.125-6hz)Relay Contacts: Form \"C\", 7A @ 30VDC, 10 A @ 125VACSize: 4.4\" x 3\"x 1.15\"Trigger Voltage: 9 - 14VDCTrigger Current: 15mA 2303122 762158009419 0.3600lbs 0.00 0.00 0.00
Elk Products
27.8000 2025-04-19 Out of Stock

Elk Products Alarm Output Director; Separates single output to 2, ELK-941

Brand Elk Products
See other products from TOS

UPC: 762158009419
SKU: TOS-ELK-941
Price:
$27.80Free shipping on orders over $75 on select TOS- items. Details
Quantity:
Out of Stock
*  Click "Add to Shopping List" to save the item for later purchase. You can receive a notice email when it is back in stock.
Share & Earn 10% Cash Back Best Price in Bulk

Pricing Note

Free Shipping Promotion: Buy more items from the same series, product code beginning with TOS-, and you can get free shipping for an order of over  $75.00  consisting of only TOS- series products.

Product Description

Manufacturer part number: ELK-941

The ELK-941 separates the steady or pulsing voltage from a single alarm output and directs this into two (2) different relay outputs. This is ideal for activating a two channel long-range radio or cellular transmitter, a two channel siren, strobe light, or bell from the single alarm outputs found in most alarm control panels. A steady voltage input activates Relay 1 (typical for burglary) while a pulsing voltage input activates Relay 2 (typical for fire). A 3 to 4 second verification delay time occurs before the relays activate. Either relay can be set to ignore the delay time and provide an immediate output for installations requiring a siren or bell test. A separate output is available for triggering a low current sounder or LED during the delay time. An optional jumper configures Relay 2 to pulse in a temporal coded bell pattern which meets ANSI Standard S3.41 for fire signaling. The input trigger can be either positive or negative (pull to ground).
Features
  • Separates Steady and Pulsing Voltage and directs it into Two (2) Different Relay Outputs
  • Positive or Negative Low Current Trigger
  • Two (2) SPDT Relay Outputs
  • Ideal For Two (2) Channel Long Range Radio or Cellular Transmitters
  • Option For Temporal Pulse On Relay 2
  • Low Current Output During Delay Time
  • LED Indication of Relay Status
  • Surface Mount ABS Enclosure with Snap-On Cover
  • Meets ANSI S3.41 Audible Emergency Evacuation Signals 3-Pulse Pattern
  • Lifetime Limited Warranty

  • Specifications:
  • Operating Voltage: 12 Volts DC
  • Current Draw: 96mA (both relays on)
  • Pulsing Input: .1 - 4sec. (.125-6hz)
  • Relay Contacts: Form "C", 7A @ 30VDC, 10 A @ 125VAC
  • Size: 4.4" x 3"x 1.15"
  • Trigger Voltage: 9 - 14VDC
  • Trigger Current: 15mA
  • warning tips WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov.

    Note

    This product is not eligible for coupon code discount, for we've been offering the best price in the market.
    Need more information?
    Our staff are available to answer any questions you may have about this item


    Customer Reviews
    0 reviews
    Be the first to review this item!